Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Pusat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • HIOKI 3286-20 CLAMP ON POWER HiTESTER
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.

HIOKI 3286-20 CLAMP ON POWER HiTESTER

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HIOKI 3286-20 CLAMP ON POWER HiTESTER

Keterangan Functionality and Safety Packed into a Handheld Unit : * Use as a single-phase power meter * Measure phase on a single-phase line * Simple checking of three-phase lines * Check power supply fluctuations * For harmonic suppression * External output of data to PC * Printer output to 9442 ( optional) Basic specifications : Measurement lines : Single-phase/ two-wires, Three-phase/ three-wires ( balanced load only) Measurement items : Voltage, current, voltage/ current peak, effective/ reactive/ apparent power( Single-phase or 3-phase) , power factor, reactivity, phase angle, frequency, phase detection( 3-phase) , voltage/ current harmonic levels( up to 20th) Measurement ranges : Voltage: 150.0 V to 600 V, 3 ranges, Current: 20.00 to 1000 A, 3 ranges, Power: 3.000 kW to 1200 kW, 18 combination patterns, Note: 3-phase power is calculated and displayed on the basis of a balanced, 50/ 60 Hz, sine wave input. For apparent power and reactive power, the unit of watts in the above table is replaced by VA and var respectively. Basic accuracy at 50/ 60 Hz, COS Ø = 1 : Power/ single-phase: ± 2.3 % rdg. ± 5 dgt., Power/ 3-phase: ± 3.0 % rdg. ± 10 dgt. ( at balanced load) Voltage / Current accuracy : Voltage: ± 1.0 % rdg. ± 3 dgt., Current: ± 1.3 % rdg. ± 3 dgt. ( at 45 to 66 Hz) Frequency characteristics : AC current : 45 to 1 kHz AC voltage : 30 to 1 kHz Other functions : Phase detection, Record ( Max. value/ Min. value) , Battery capacity display, Data hold, Auto power off, Data output ( RS-232C interface by optical insulating coupler) Display update rate : NORMAL: approx. 1 time/ sec, SLOW: 1 time/ 3-sec, HARM meas.: approx. 1 time/ 2-sec Power supply : 6LR61 alkaline battery × 1 ( continuous operation max. 25 hours) , 6F22 manganese battery × 1 ( continuous operation max. 10 hours) Dimensions, mass : 100 mm( 3.94 in) W × 287 mm( 11.3 in) H × 39 mm( 1.54 in) D, 650 g ( 22.6 oz) Core jaw dia.: Ø 55 mm( 2.17 in) or 80 mm ( 3.15 in) × 20 mm ( 0.79 in) busbar Accessories : VOLTAGE CORD 9635 ( 1) , CARRYING CASE 9245, ( 1) , Hand strap ( 1)
Tampilkan Lebih Banyak